Introduction
This kit integrates two output modes, regular DC (direct current) output mode and new Pulse output mode. Heating accelerates and vapor is enhanced. More vapor produced under the same voltage or wattage.
Main features:
Airflow control adjustable
Stainless Steel
2 output modes available, creative PULSE output
Variable voltage and wattage
USB passthrough function
Ohms meter
Settings memory function
LCD display
General protections like, short circuit protection, over-charge and discharge protection, 5-click lock, atomizer protection
Order Tips
1. It comes with 510/eGo thread.
2. Two color options for battery, matte black and steel
Including |
|
vAir D16 Clear Atomizer (1.8ohm dual-coil unit pre-installed) |
1pc |
vPulse 900mAh Manual Battery |
1pc |
Replacement Dual-coil unit (2.2ohm) |
1pc |
Decorative Ring |
1pc |
USB Cable |
1pc |
Manual(English) |
1pc |
Size: |
|
length(cartomizer loaded) |
200mm |
diameter |
17mm |
Detailed Introduction
Operation Guide
1. vPulse Battery Usage
There’re three buttons on vPulse battery. All functions can be activated by using those three buttons.
1.1 Buttons:
“O” button, turn on/off the battery, press to smoke and switch output mode – DC and Pulse
“+” button, increase voltage and wattage, switch between VV and VW mode
“-” button, decrease voltage and wattage, and detect real-time resistive load
1.2 On/Off:
In off status, continuous click “O” button 5 times within 2 seconds to enter into working status; in working status, continuous click “O” button 5 times within 2 seconds to turn the battery off.
1.3 Output Mode:
1. DC mode: In off situation, press the “O” button and release until white light blinks. It enters into DC output mode after it’s turned on.
2. Pulse mode: In off situation, press the “O” button and release until blue light blinks. It enters into Pulse output mode after it’s turned on.
3. Both voltage and wattage can be adjusted under each mode.
1.4 VV/VW Changing-over:
1. From VV to VW: Press “+” button for 5 seconds and “O” button blinks 3 times to show changing-over succeeds. Then wattage can be changed from 3W to 12W in 0.5 increments. The LCD shows “w” to indicate it’s in VW mode.
2. From VW to VV: Press “+” button for 5 seconds and “O” button blinks 3 times to show changing-over succeeds. Then voltage can be changed from 3.0V to 5.0V in 0.1 increments. The LCD shows “v” to indicate it’s in VV mode.
1.5 Ohms Meter:
In working status, keep pressing “-” button for 5 seconds, the battery will detect current atomizer resistance and show the result on LCD screen for 3 seconds.
1.6 Battery Level Indicator:
The LCD battery icon displays real-time battery power and the battery indicator is independent of other information on the LCD screen:
<3.3v, empty display;
3.3v - 3.6v, one frame display;
3.6v - 3.8v, two frames display;
3.8v - 4.0v, three frames display;
>4.00v, full frames display.
1.7 Parameters Lock:
In working status, press “+” and “-” button at the same time for 3 seconds to turn on or turn off parameters lock. If the LCD screen shows a lock symbol, variable voltage, variable wattage and resistance detection functions aren’t useable.
1.8 Charging:
Connect the Micro-USB cable to a computer or an AC-USB adapter into a power outlet to charge the battery. The battery icon will run up from current display repeatedly. Full frames display shows the battery is fully charged.
2. vAir Clear Atomizer Usage
2.1 How to adjust airflow?
To increase airflow, please rotate the airflow control valve clockwise;
To decrease airflow, please rotate the airflow control valve counter-clockwise.
Rotate the airflow control valve to the most comfortable one for you.
2.2 How to refill e-liquid?
1. Turn upside down the clear atomizer, and then screw off the bottom base.
2. Fill liquid into the space between the glass tank and center metal tube. DO NOT over fill or get liquid into the center hole.
3. Carefully screw the bottom base back onto the upper hardware.
4. Let the clear atomizer stand for 2 minutes before use. It can let e-liquid absorbed into the wick/atomizer chamber to avoid burning taste.
2.3 How to change replacement coil?
First, turn upside down the clear atomizer and screw off the bottom base.
Second, disconnect the old coil unit from the bottom base, replace with a new one.
Last, screw the base back to the tube tightly.